Stainless Steel Wheel Centrifugal Fan/Centrifugal Fan Wheel

Model NO.: XH-BF-12
Speed: 960/730/1450/580/480 R/M
Motor Power: 15-2000kw
Volume: 11000-667000m³/H
Machine No.: 20 Machine Number
Total Pressure: 955~9460 PA
Color: Blue/Yellow/Green/Customized
Customized: Design and Technical Drawing Can Be Customized
Accessory: Foundation Bolt/Nuts/Gaskets
Accessories: Foundation Bolt/Nuts/Gaskets/Coupling
Trademark: Kuang Feng
Transport Package: Strong Wooden Case Exporting Standard
Specification: Adjustable Aluminum Blades
Origin: China
HS Code: 8414599099
Model NO.: XH-BF-12
Speed: 960/730/1450/580/480 R/M
Motor Power: 15-2000kw
Volume: 11000-667000m³/H
Machine No.: 20 Machine Number
Total Pressure: 955~9460 PA
Color: Blue/Yellow/Green/Customized
Customized: Design and Technical Drawing Can Be Customized
Accessory: Foundation Bolt/Nuts/Gaskets
Accessories: Foundation Bolt/Nuts/Gaskets/Coupling
Trademark: Kuang Feng
Transport Package: Strong Wooden Case Exporting Standard
Specification: Adjustable Aluminum Blades
Origin: China
HS Code: 8414599099
Stainless Steel Wheel Centrifugal Fan/Centrifugal Fan Wheel


Product Display
Stainless Steel Wheel Centrifugal Fan/Centrifugal Fan Wheel


Usage 
XH-BF-12 Centrifugal Fan blower is mainly used in 2t / h ~ 670t / h steam boiler ventilation in the thermal power plant, and it can also meet the high pressure head performance parameters of fluidized bed furnace. This series fans can also be used for dust, mine fan General ventilation system.
Stainless Steel Wheel Centrifugal Fan/Centrifugal Fan Wheel

XH-BF-12 Centrifugal Fan blower is for 35t / h ~ 410t / h circulating fluidized bed boiler feed system, the system fan can also be used for dust, mine ventilation and general ventilation system.
The medium for the blower is air, and the medium for the draft fan is flue gas or particulate matter containing impurities. If the impurity concentration is less than 200mg / m3, the impeller can be used for more than five years. If the impurity is large, the service life is shortened and the maximum temperature of the blower can not exceed 250 ºC.


Model Series
XH-BF-12 type Centrifugal Fan have total 20 machine No. and 40 specification, from No.8D~29.5D

Parameters
BF-12 Performance&Parts   

Here's part of parameters.
More specification please contact us to get latest catalog and performance curve.
Machine
No.
Speed
r/min
Total
Pressure
Pa
Volume
m
3/h
Internal Efficiency
%
Internal
Power
kw
Shaft Power
kw
Required
Power
kw
Motor
Power
kw
8D 1450 2745
2701
2612
2479
2346
2214
2036
1859
11000
13200
15400
17600
19800
22000
24200
26400
75
78
81
83
82
80
77
74
11.2
12.7
13.8
14.6
15.7
16.9
17.8
18.4
11.4
13
14.1
14.8
16.1
17.3
18.1
18.8
13.1
14.9
16.2
17
18.5
19.8
20.9
21.6
15
18.5
22
9D 1450 3474
3418
3306
3138
2969
2801
2577
2353
15700
18800
21900
25000
28100
31300
34400
37500
75
78
81
83
82
80
77
74
20.2
22.9
24.8
26.3
28.3
30.4
32
33.1
20.6
23.4
25.3
26.8
28.8
31.1
32.6
33.8
23.7
26.9
29.1
30.8
33.2
35.7
37.5
38.9
30
45
10D 1450 4289
4220
4081
3874
3666
3459
3182
2905
21500
25800
30000
34300
38600
42900
47200
51500
75
78
81
83
82
80
77
74
34.2
38.8
42
44.5
47.9
51.5
54.2
56.2
34.9
39.6
42.8
45.4
48.9
52.6
55.3
57.3
40.1
45.5
49.3
52.2
56.3
60.5
63.6
65.9
45
55
75
11D 1450 5190
5106
4938
4688
4436
4185
3850
3515
28600
34300
40000
45700
51400
57100
62800
68500
75
78
81
83
82
80
77
74
55
62
68
72
77
83
87
90
56
64
69
73
79
85
89
92
65
73
79
84
91
97
102
106
75
90
110
Machine No. Speed
r/min
Total Pressure
Pa
Capacity
m3/h
Internal Efficiency
%
Internal Power
kw
Shaft Power
kw
Required Power
kw
Motor
Power
kw
11D 960 2275
2238
2164
2055
1944
1834
1688
1541
18900
22700
26500
30300
34000
37800
41600
45400
75
78
81
83
82
80
77
74
15.9
18.1
19.7
20.8
22.4
24.1
25.3
26.3
16.3
18.5
20.1
21.3
22.8
24.6
25.8
26.8
18.7
21.2
23.1
24.5
26.3
28.2
29.7
30.8
22
30
12D 1450 6176
6077
5877
5579
5279
4981
4582
4183
37100
44600
51800
59300
66700
74100
81600
89000
75
78
81
83
82
80
77
74
85
97
104
111
119
128
135
140
87
98
107
113
122
131
138
143
100
113
123
130
140
150
158
164
110
132
160
12D 960 2707
2664
2576
2445
2314
2183
2008
1834
24600
29500
34300
39300
44200
49100
54100
59000
75
78
81
83
82
80
77
74
24.7
28
30.3
32.2
34.6
37.2
39.2
40.6
25.2
28.6
30.9
32.8
35.4
38
40
41.4
28.9
32.8
35.6
37.7
40.7
43.7
46
47.7
37
45
55
13D 1450 7248
7132
6897
6547
6196
5846
5378
4909
47200
56700
65900
75400
84800
94300
104000
113000
75
78
81
83
82
80
77
74
127
144
156
165
178
191
202
208
129
147
159
169
182
195
206
212
149
169
183
194
209
225
237
244
185
200
250
Complete sets of supply

1, A fan

2, Foundation bolts 1 set

3, Coupling guard 1 set

4,Thermometer 8-16 for the two bimetallic live contact thermometer, 17-31.5F2 only bimetallic thermometer and two platinum thermal resistance.

5, Outlet and inlet soft connection.

6, The motor (without electrical equipment) one (subject to the contract)


Ordering instructions
When ordering Centrifugal Fan blower types, please specify the fan number, speed, air volume, wind pressure, outlet angle and direction of rotation, as well as motor model, power, speed and so on.
The most important factors are volume and pressure.

 

To make the proper fan selection, you must consider the following system conditions the fan will be subjected to:

1. What is the required airflow?
This is rated in cubic feet of air per minute (CFM) or, in metric equivalent, it is rated in cubic meters of air per hour (M³/Hr).

2. What is the static pressure through the complete system?
This is rated in static pressure water gauge (SP) or, in metric equivalent, it is rated in Pascal's (Pa).

3. What is the ambient air temperature outside the fan?

4. What will be the airflow conditions through the fan?

A.    Clean or dirty (contaminated) air?

Stainless Steel Wire

Stainless Steel Wire,Stainless Soft Wire,Wire Scourer,Stainless Steel Soft Wire

Jiangsu Manrui New Materials Co., Ltd , https://www.manruiwire.com